Description
LCR Meter IM3533 measurement methods: Continuous measurement using different sets of conditions
The Hioki IM3533 LCR Meter can perform continuous measurement using different capacitor measurement conditions, for example to perform C-D measurement at 120 Hz and ESR measurement at 100 kHz, without stopping to manually change settings.
LCR Meter IM3533-01 measurement methods: Frequency sweep measurement
The IM3533-01 can perform automatic measurement while sweeping through up to 801 frequencies from a user-specified frequency range or frequency list. Measurement results can be saved on a USB flash drive or computer via the instrument’s interface in order to create lists and graphs of frequency characteristics using the included LCR application software.
Probes and Test Fixtures (15)
When using the 9268-10 or 9269-10, external constant-voltage and constant-current sources are required.
SMD TEST FIXTURE IM9100
Learn more
• Direct-connection testing
• Test SMDs with electrodes on the bottom
• DC to 8MHz
• Measurable sample sizes: 01005 to 0402 (EIA)
Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high
Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)
To replace the tip on the L2001, small size
Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
PINCHER PROBE L2001
Learn more
• DC to 8MHz, 50Ω termination
• Tip electrode spacing: 0.3 to 6 mm
• Measurable sample size: 0603 (EIA)
Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A
Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V
Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)
To replace the tip on the L2001, regular size, bundled with the L2001
SMD TEST FIXTURE IM9110
Learn more
• For direct connection two-wire testing
• DC to 1 MHz
• Measurable sample size: 008004 (EIA)
PC Communication (4)
2 m (6.56 ft) length
Temperature Measurement (1)
Pt100, Tip dia. φ2.3 mm (0.09 in), Cord length 1 m (3.28 ft), Waterproof construction
*This product is not supplied with measurement probes or test fixtures.
Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable.For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.
Basic Specifications
IM3533 | IM3533-01 | |||||
Measurement modes | LCR (Measurement with single condition), Transformer testing (N, M, ΔL), Continuous testing(Continuous measurement under saved conditions) (LCR mode) | LCR (Measurement with single condition), Transformer testing (N, M, ΔL), Analyzer (sweep testing), Continuous Testing (LCR/Analyzer mode) | ||||
Measurement parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), N, M, ΔL, T | |||||
Measurement range | 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.) | |||||
Displayable range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y only θ: ± (0.000° to 180.000°), D: ± (0.00000 to 9.99999) Q: ± (0.00 to 99999.9), Δ%: ± (0.0000% to 999.999%), T: -10.0°C to 99.9°C |
|||||
Basic accuracy | Z : ±0.05% rdg. θ: ±0.03° | |||||
Measurement frequency | 1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz) | |||||
Measurement signal level | [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps CC mode: 10 μA to 50 mArms, 10 μArms steps [Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps CC mode: 10 μA to 100 mArms, 10 μArms steps |
|||||
Output impedance | Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω | |||||
Display | 5.7-inch touch-screen color TFT, display can be set to ON/OFF | |||||
Measurement time | 2 ms (1 kHz, FAST, display OFF, representative value) | |||||
Functions | DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function | |||||
Interfaces | EXT I/O (Handler), USB communication (high-speed), USB memory Optional: Choose 1 from RS-232C, GP-IB, or LAN |
|||||
Power supply | 100 to 240 V AC, 50/60 Hz, 50 VA max | |||||
Dimensions and mass | 330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz) | |||||
Accessories | Power cord × 1, Instruction manual × 1, CD-R (Includes PC commands and sample software) × 1 |