Description
Included Accessory (1)
Tips 4 wires, 1 m (3.28 ft) length
Data Acquisition Accessories (2)
For data acquisition to PC
COMMUNICATION ADAPTER LR5091
Learn more
• Transfer data from logger to PC
• Transfer setting/clock data from PC to logger
• Free bundled software
DATA COLLECTOR LR5092
Learn more
• Collect up to 60,000 data x 16 channels from LR5000 series loggers
• Transfer data from logger to PC
• Transfer setting/clock data from PC to logger
• Free bundled software
For Fixing (2)
Not compatible with Model LR5051
Basic Specifications
LR5041 | LR5042 | LR5043 | ||||
Measurement items | DC voltage 1ch | DC voltage 1ch | DC voltage 1ch | |||
Measurement range | -50.00 to 50.00 mV | -5.000 to 5.000 V | -50.00 to 50.00 V | |||
Accuracy | ±0.5 %rdg. ±5 dgt. | |||||
Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data | |||||
Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections | |||||
Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
|||||
Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
|||||
Other functions | Pre-heat function (requires external power supply during use of function), Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced | |||||
Waterproof and dust-proof | IP54 (EN60529) (with connection cable connected, but not including cable tip) | |||||
Interfaces | Infrared optical communications with LR5091, LR5092-20 | |||||
Power supply | LR6 (AA) Alkaline battery ×1, Battery life: Approx. 2 years (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2 months (Instantaneous recording, with 1-second interval at 20 °C) | |||||
Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) | |||||
Accessories | LR6 (AA) Alkaline battery (built-in internal) ×1, Connection cable LR9802 ×1, Instruction manual ×1, Operation guide ×1, Kickstand ×1 |