Products



HOBO UX100-003 – Temp/RH 3.5% Data Logger

$295.00 Ex GST

The HOBO UX100-003 Temp/RH data logger records temperature and relative humidity (within 3.5% accuracy) in indoor environments.
Read full description and specs

$
Categories: ,

Description

Description

The HOBO UX100-003 Temperature/Relative Humidity data logger records temperature and relative humidity (within 3.5% accuracy) in indoor environments with its integrated sensors. The data logger is ideal for monitoring occupant comfort in office buildings, tracking food storage conditions in warehouses, logging temperature trends in server rooms, and measuring humidity levels in museums.

Highlighted Features

  • Easy-to view LCD display
  • Large memory capacity
  • Visual high & low alarm thresholds
  • New Burst and Statistics logging modes
  • User-replaceable Relative Humidity sensor
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?
This data logger operates in an indoor environment.

What measurements does this data logger support?
The UX100-003 data logger supports the following measurements: Relative Humidity and Temperature


IMPORTANT: 
This HOBO data logger requires HOBOware software and a communications device (USB Cable). See compatible items below and the “software” tab above.
 

Whats in the box:

  • HOBO UX100-003 Temp/RH 3.5% Data Logger
  • Commandâ„¢ strip
  • Double-sided tape
  • Hook & loop strap

Temperature Sensor


Range: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Resolution: 0.024°C at 25°C (0.04°F at 77°F)
Response time: 4 minutes in air moving 1 m/s (2.2 mph)
Drift: <0.1°C (0.18°F) per year

 

RH Sensor


Range: 15% to 95% (non-condensing)
Accuracy:
±3.5% from 25% to 85% including hysteresis at 25°C (77°F); below 25% and above 85% ±5% typical
Resolution: 0.07% at 25°C (77°F) and 30% RH
Response time: 43 seconds to 90% in airflow of 1 m/s (2.2 mph)
Drift: <1% per year typical

 

Logger


Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification

Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: ±1 minute per month at 25°C (77°F)
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 128 KB (84,650 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 20 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50

Additional information

Weight 1 kg
Dimensions 20 × 15 × 10 cm

SYDNEY MELBOURNE BRISBANE ADELAIDE PERTH

Sydney

Unit 1, 88 Magowar Rd, Girraween, 2145

Melbourne

11/5 Agosta Drive, Laverton North, 3026

Adelaide

3A Wilford Ave, Underdale, 5032

Brisbane

2D/919 Nudgee Road Banyo QLD 4014

Perth

1/19 Industry St Malaga WA 6090

Call Us

Phone: 1300 669 162