YOKOGAWA ADMAG TI Series AXG Electromagnetic Flowmeter

$3,300.00 Ex GST

The ADMAG TI (Total Insight) series AXG electromagnetic flowmeter is a high-quality and highly reliable product developed based on years of experience and achievement, such as enhancement of application by our proprietary dual frequency excitation method.

Read full description and specs

Description

  • Backward Compatibility between High Grade Remote Transmitter AXG1A and AXFA11
    High Grade Remote Transmitter AXG1A is the successor to AXFA11.
    As with AXFA11, combined connection with AXF/AXG/AXW Flow sensors is possible.
    The position of the input/output terminals and the hole position of the stanchion mounting position are inherited, making it easy to replace AXFA11 with AXG1A.
    Terminal Configuration
  • Cable Connection Checking Function

When installing multiple transmitters and detectors at one time, have you ever made a mistake in connecting cables?

Cable Connection Checking Function

ADMAG AXG diagnoses whether the transmitter and detector are connected in the correct combination. This helps reduce start-up wasted time caused by incorrect cable connections.

  • Detection of Flow Noise (Air bubbles, Slurry)

Even with conventional models, we have provided stable flow measurement using our dual-frequency excitation method, our proprietary signal processing technology.

Furthermore, ADMAG AXG can display and output the strength of flow noise separately from flow signal output. As a result, while realizing stable flow rate measurement, it is possible to grasp when flow noise is generated at “when,” “how long,” and “how much strength”, thus contributing to flow noise countermeasures.

Detection of Flow Noise (Air bubbles, Slurry)

 

Data Logging Function

Items Parameters
Recordable Data PV, Velocity, Volume flow, Mass flow, Calorie, Flow Noise Value, Resistance Value of the electrode Adhesion Detection, Voltage of Electrodes (A, B), Peak Value of the Flow Rate Signal
Interval Time 1s, 10s, 30s, 1m, 5m, 30m, 1h
Recordable Time 10m, 30m, 1h, 3h, 12h, 24h, 72h, 240h

 

Technical Information

Datasheet

 

FEATURES

  • Stable Measurement
    Our own dual frequency excitation method realizes stable flow measurement even under high flow noise in the fluid with highly concentrated slurry.
  • Multiple Inputs and Outputs
    Maximum four inputs/outputs of current, pulse, and status signals can be selected. Mass or calorie calculation using temperature input is available.
  • Improved Operation and Monitoring Function
    Operation authority level setting for ensuring safety, process data trend display, display backlight flashing (Squawk) function, and data store / restore function with display unit internal memory or microSD card are available.
  • Improved Maintainability
    Diagnostic functions that contribute to preventive maintenance of the plant are installed. Diagnosis of the device (verification function) that can be executed without demounting from piping, detection of the process condition by monitoring the flow noise and electric conductivity of the fluid, electrode insulation deterioration diagnosis, electrode adhesion diagnosis, and wiring connection diagnosis are available.
  • Communication Protocol

HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA

Refer to GS 01E21F02-01EN for FOUNDATION Fieldbus communication type
Refer to GS 01E21F02-03EN for PROFIBUS PA communication type

Refer to GS 01E22A11-03EN for pulp & paper application type
Refer to GS 01E22A21-04EN for marine approval type

Additional information

Weight 7 kg
Dimensions 600 × 500 × 400 cm

YOKOGAWA ADMAG TI Series AXG Electromagnetic Flowmeter Datasheet

SYDNEY MELBOURNE BRISBANE ADELAIDE PERTH

Sydney

Unit 1, 88 Magowar Rd, Girraween, 2145

Melbourne

11/5 Agosta Drive, Laverton North, 3026

Adelaide

3A Wilford Ave, Underdale, 5032

Brisbane

2D/919 Nudgee Road Banyo QLD 4014

Perth

1/19 Industry St Malaga WA 6090

Call Us

Phone: 1300 669 162