Description
Series TT01 Cap Torque Testers are designed to measure application and removal torque of bottle caps up to 100 lbFin [11.5 Nm].
Class-leading accuracy of ±0.3% and blazingly fast sampling rate of 7,000 Hz ensure reliable and consistent test results, even in quick-action applications. Password protection is provided to prevent unauthorized changes to settings and calibration.
The TT01 includes a range of sophisticated productivity-enhancing features, including USB, RS-232, Mitutoyo, and analog outputs, automatic data output and zeroing upon cap removal, memory storage for 1,000 readings, pass/fail indicators and outputs, and more. First / second peak torque detection is useful for measuring slip and breakaway torques for tamper evident closures.
Series TT01 testers include MESUR® Lite data acquisition software. MESUR® Lite tabulates continuous or single point data. Data stored in the TT01’s memory can also be downloaded in bulk. One-click export to Excel allows for further data manipulation.
Features Include
- Moveable 1.25″ (31 mm) length posts accommodate a wide range of sample shapes and sizes
- Available extended post lengths and other gripping options
- USB, RS-232, Mitutoyo, and analog outputs
- Automatic output, data storage, and zeroing upon bottle cap removal helps automate testing processes
- First / second peak detection for slip and breakaway torques in tamper evident closures
- 1,000-point data memory with statistics and outputs
- Password protection prevents unauthorized changes
- Programmable set point indicators and outputs for pass/ fail determination
- High-speed 7,000 Hz sampling rate accurately captures peak torque values
- Configurable audio alarms and key tones
- 5 selectable units of measurement
- MESUR® Lite data collection software included
Technical Specifications
Accuracy |
±0.3% of full scale |
Sampling rate |
7,000 Hz |
Power |
AC or rechargeable battery. Multi-step low battery indicator is displayed, gauge shuts off automatically when power is too low. |
Battery life |
Backlight on: up to 7 hours of continuous use |
Backlight off |
up to 24 hours of continuous use |
Measurement units |
ozFin, lbFin, kgFcm, Nm, Ncm |
Output |
lbF, gF, kgF, N (depending on model) |
Mitutoyo (Digimatic) |
Serial BCD suitable for all Mitutoyo SPC-compatible devices |
Analog |
±1 VDC, ±0.25% of full scale at capacity |
General purpose |
Three open drain outputs, one input |
Set points |
Three open drain lines |
Configurable settings |
settings: Digital filters, outputs, automatic output/data storage/zero, automatic shutoff, default settings, key tones, backlight, audio alarms, passwords, calibration |
Safe overload |
150% of full scale (display shows “OVER” at 110% and above) |
Weight |
8.4 lb [3.8 kg] |
Environmental requirements |
40°F – 100°F [5°C – 45°C], < 96% humidity (non-condensing) |
Warranty |
3 years (see individual statement for further details) |