Products



HIOKI DT4281 High End Digital Multimeter

$850.00

Designed and Manufactured in Japan to ensure High Quality Measurements

World’s Premier Digital Multimeter. Superior Accuracy and High Response, Topped with Safety Terminal Shutters

 

  • L9207-10 Test Leads Included!
  • Connect to PC in real time with optional DT4900-01 Communication Package
  • Compatible with additional Current Clamps attachments with Optional 9704 Conversion Adaptor

*Not compatible with Z3210 Wireless Adaptor and Gennect Cross Software – only DT4261

 

Read full description and specs

SKU: DT4281 Categories: , , Tags: ,

Description

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters.

The DT4281 is our top-of-the-line high-precision 60000 count digital multimeter with all of the functions and features required for advanced testing in complex power and electrical applications.

CAT IV 600 V, CAT III 1000 V

 

The ultimate digital multimeter, featuring a design focused on safety that’s critical for electrical work

The DT4281, which is part of Hioki’s DT4280 series of high-end digital multimeters, is designed for maximum safety in electrical work. Connect an AC clamp to safely measure current.

– DC current measurement 600.00μA / 6000.0μA / 60.000mA / 600.00mA
– AC current measurement 600.00μA / 6000.0μA / 60.000mA / 600.00mA
– Directly connect an AC clamp sensor

 

Safe measurement requires use of an instrument that suits the measurement location.

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.

 

Measurement data can be downloaded to, reviewed on, and saved to a computer.

Connect the DT4281 to a PC with the optional Communication Package DT4900-01 to easily graph data stored in the DMM’s internal memory and display measurement results in real time on the computer. Save important measured values in text format.

*The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.

 

Percentage display for 4 to 20 mA instrumentation signals

The digital multimeter can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal.

 

Basic Specifications

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage* range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz – 100 kHz
Basic accuracy 45 – 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC Voltage* range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz – 100 kHz
Basic accuracy 45 – 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC Current range 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC Current* range 600.00 μA to 600.00 mA, 4 ranges
Basic accuracy 45 – 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz – 20 kHz (at 600 μA to 600 mA range)
AC Current* range
(use with Clamp on probes)
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy 40 – 65 Hz : ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3)
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated)
Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature (thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion
Display Main and sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supply LR6 (AA) alkaline batteries × 4, Continuous use: 100 hours
Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
Accessories Test Lead L9207-10 × 1, Instruction Manual × 1, LR6 Alkaline Battery × 4
  • *Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed.

Additional information

Weight 2 kg
Dimensions 20 × 30 × 15 cm

Pickup at a NWI Office Location

If you do not want to pay for delivery or need to receive the item ASAP, you can pick the item up at one of our five (5) Australian offices. Just bear in mind not all offices will have everything in stock. Please call our 1300 669 162 number to see if your item is in stock at your local office.  

Interstate Deliveries:

Delivery costs are based off your location in Australia. NWI Group uses TNT Australia for all domestic deliveries.  

Estimated Delivery Timeframe:

If you opted to collect at a NWI office location, you will receive an email to inform you when your goods are ready for collection. If you opted for delivery, you would receive an email when the goods have been despatched to the couriers with details so you can track your order. We aim to despatch all orders within 1-2 business days. In the unusual event of a delay to the despatch of your order you will be contacted at the earliest opportunity. Once the order has been despatched the estimated delivery time is as follows:
  • Metro (Exclude: Hobart Metro) 1 -2 business day:
  • Hobart Metro 3-4 business days
  • Regional Areas: 3-4 business days:
  • Remote Areas: 6-9 business days
Please note that these delivery timeframes are estimates and are not guaranteed.  

Returns Policy

Changed your mind? No worries. You just need to get the product back to the NWI office it was shipped from (this is on your receipt) within 30 days, unused and in its original packaging and we will give you a refund (excluding delivery costs – terms and conditions apply) Special order items are excluded from this returns policy.

General Data Sheets

HIOKI Digital Multimeter DT4200 Series - NWI

HIOKI DT4900 Communication Package - NWI

Why Choose NWI?

Since its inception in 1994, NWI Group has been committed to providing a service of quality in the sale, calibration and service of measuring equipment used in laboratories and manufacturing companies. Our strive for continuous improvement is part of our quality policy statement. A family-owned business, we have offices throughout Australia. Our product range covers fine precision measuring equipment to large industrial weighbridges, process instrumentation and automation software. Our calibration services for process and laboratories through our NATA accreditation guarantees our commitment to correct measurement and customer satisfaction.

Our Mission

It is our aim to provide our customers with levels of service that consistently exceed their expectations. This recognises that the customers ongoing, long-term relationship is crucial for business growth and development.

Our Vision

Provide individuals and companies with high quality and reliable measuring equipment, technology, and calibration services now and for future generations.

Accreditations:

NATA Accreditation for:
  • Mass & Weighing
  • Volume & Density
  • Electrical Metrology
  • Time & Frequency Metrology
  • Temperature & Humidity Metrology
NMI Trade Measurement Servicing Licence for Weighing & Mass.

SYDNEY MELBOURNE BRISBANE ADELAIDE PERTH

Sydney

Unit 1, 88 Magowar Rd, Girraween, 2145

Melbourne

11/5 Agosta Drive, Laverton North, 3026

Adelaide

3A Wilford Ave, Underdale, 5032

Brisbane

2D/919 Nudgee Road Banyo QLD 4014

Perth

1/19 Industry St Malaga WA 6090

Call Us

Phone: 1300 669 162