Products



HIOKI LR5001 Temp/Humidity Logger

$555.00 Ex GST

 

Record Temperature and Humidity Simultaneously with Dual-Channel Data Logger

 

  • Compact and Light Weight Design
  • Ideal for basic environmental monitoring applications
  • 1 or 2 Channels with fast sampling intervals of up to 1 second
  • Additional sensors available for longer length requirements

 

Read full description and specs

Description

Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals.

 

The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals.

 

Optional Sensors:

LR9504 is an included sensor

 

Basic Specifications

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
Measurement items Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor)
Measurement range Temperature: -40.0°C to 85.0°C, Humidity: 0 to 100% RH at sensor environment
Basic accuracy [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C)
[Humidity] : ±5 % rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh)
Note: Basic accuracy is typical value, refer to the detailed catalog
Storage capacity Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Recording modes Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
Recording methods One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data is overwritten)
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Other functions Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low
Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement)
Waterproof and dust-proof IP54 (EN60529) (with sensor connected, but not including sensor tip)
Interfaces Infrared optical communications with LR5091, LR5092-20
Power supply LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz)
Accessories LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1

 

Additional information

Weight 2 kg
Dimensions 30 × 30 × 30 cm

Pickup at a NWI Office Location

If you do not want to pay for delivery or need to receive the item ASAP, you can pick the item up at one of our five (5) Australian offices. Just bear in mind not all offices will have everything in stock. Please call our 1300 669 162 number to see if your item is in stock at your local office.  

Interstate Deliveries:

Delivery costs are based off your location in Australia. NWI Group uses TNT Australia for all domestic deliveries.  

Estimated Delivery Timeframe:

If you opted to collect at a NWI office location, you will receive an email to inform you when your goods are ready for collection. If you opted for delivery, you would receive an email when the goods have been despatched to the couriers with details so you can track your order. We aim to despatch all orders within 1-2 business days. In the unusual event of a delay to the despatch of your order you will be contacted at the earliest opportunity. Once the order has been despatched the estimated delivery time is as follows:
  • Metro (Exclude: Hobart Metro) 1 -2 business day:
  • Hobart Metro 3-4 business days
  • Regional Areas: 3-4 business days:
  • Remote Areas: 6-9 business days
Please note that these delivery timeframes are estimates and are not guaranteed.  

Returns Policy

Changed your mind? No worries. You just need to get the product back to the NWI office it was shipped from (this is on your receipt) within 30 days, unused and in its original packaging and we will give you a refund (excluding delivery costs – terms and conditions apply) Special order items are excluded from this returns policy.

General Data Sheet

series_LR5000E23-12M

Application Examples

Temperature and Humidity Application Note

Why Choose NWI?

Since its inception in 1994, NWI Group has been committed to providing a service of quality in the sale, calibration and service of measuring equipment used in laboratories and manufacturing companies. Our strive for continuous improvement is part of our quality policy statement. A family-owned business, we have offices throughout Australia. Our product range covers fine precision measuring equipment to large industrial weighbridges, process instrumentation and automation software. Our calibration services for process and laboratories through our NATA accreditation guarantees our commitment to correct measurement and customer satisfaction.

Our Mission

It is our aim to provide our customers with levels of service that consistently exceed their expectations. This recognises that the customers ongoing, long-term relationship is crucial for business growth and development.

Our Vision

Provide individuals and companies with high quality and reliable measuring equipment, technology, and calibration services now and for future generations.

Accreditations:

NATA Accreditation for:
  • Mass & Weighing
  • Volume & Density
  • Electrical Metrology
  • Time & Frequency Metrology
  • Temperature & Humidity Metrology
NMI Trade Measurement Servicing Licence for Weighing & Mass.

SYDNEY MELBOURNE BRISBANE ADELAIDE PERTH

Sydney

Unit 1, 88 Magowar Rd, Girraween, 2145

Melbourne

11/5 Agosta Drive, Laverton North, 3026

Adelaide

3A Wilford Ave, Underdale, 5032

Brisbane

2D/919 Nudgee Road Banyo QLD 4014

Perth

1/19 Industry St Malaga WA 6090

Call Us

Phone: 1300 669 162